While at Intel I designed DRAMs and some researcher discovered that DRAMs were failing out in the field. These failures were being caused by Alpha particles in the ceramic packages that would strike the memory cell and change the charge in between refresh cycles, thus causing a one-time error. The solution was to literally coat [...]